Connecting rigid pvc conduit to flex pvc conduit - Electrician Talk
2016年8月19日 · Talking about gluing PVC, just finished a job where the home owner had his own trenching done, about 200ft., installed PVC Conduit in 10ft sections and glued after he installed the wire in the conduit sections. I was a bit nervous about the glue possibly damaging the wire.
PVC to non metallic liquid tight transition - Electrician Talk
2019年6月25日 · "90% of the time when Carflex (LFNC) switches over from a LFNC to a PVC or Fiberglass conduit it will terminate into a junction box. LFNC Fittings has to be used with LFNC per the NEC. It is allowed to use a LFNC Fitting with a PVC Female Fitting. The PVC fitting would solvent cement to the PVC conduit and the LFNC fitting would screw into it."
transitioning from one type of conduit to another
2018年4月19日 · Changing from non-matalic to metalic raceway, yes in theory the conduit should be bonded on both ends. Then I get all the flash backs about underground PVC to a ridgid 90 and vertical with PVC. Or a PVC stubbed out of the ground or floor to EMT. Perhaps one day a fitting manufacture will make a transition coupling that has a spot to lay in the EG.
MC cable to PVC pipe - Electrician Talk
2017年9月13日 · Also it's not a bonding issue, the MC jacket is bonded at the 1900 box from which it comes from and the female adaptor that the connector on the pipe end is PVC (no bonding to be done), MC cable has a full size ground for …
connecting rigid PVC to nonmetallic liquidtight??? - Electrician Talk
2018年10月3日 · I'm wanting to convert from rigid 1-1/4 PVC to flexible nonmetallic conduit, using a rigid pvc female adapter to a flex straight terminal (male) adapter. I believe this is compliant. I would be interested in opinions. The environment is residential, either unfinished basement or garage (or both). THX
PVC to EMT Adaptor, Exterior? - Electrician Talk
2013年6月17日 · "Hey, apprentice, go to the van and bring back 30 feet of 3/4" PVC, a 90 degree elbow, 8 couplings and a ****ing asshole." Save Share Reply Quote Like
PVC service mast - Electrician Talk
2017年2月22日 · To be compliant with the UL listing, you can not use any fitting with male threads with a rigid coupling. To meet the UL listing, if for instance you want to connect EMT and PVC without using a box, you use a EMT-to-female-thread fitting, a short length of threaded rigid conduit, and a PVC-to-female-thread fitting. Don't shoot the messenger.
PVC Conduit Belled End Orientation - Electrician Talk
2021年2月7日 · The PVC hub is cool, but if the riser is over 10 ft from the meter socket or there is a fitting like a 90 degree, you still need a coupling or a belled end to join conduit above that Save Share
Pool Light Conduit - Electrician Talk
2011年3月31日 · I'm looking at a job where a pool plastering company came in and plastered the pool and moved the pool light switch to a different location. The pool was built in 1961 and did not have a GFCI on it in the first place. The installation looks Mickey Mouse and the home owner wants it done right. They just moved the switch in 1/2" pvc.
innerduct transition - Electrician Talk
2015年4月28日 · Try the HDPE to PVC Transition couplings. 4-5years ago the company I worked for we ran miles and miles of HDPE conduit from 3/4" to 6". The 3/4-4" we used couplings very similar to these above. The couplings are like a Chinese finger with ridges on the inside. Damn near impossible to pull off.